Are you a residential pool owner considering the installation of a natural gas or propane heater? Ensuring your pool heater is installed according to the stringent codes set by the Technical Standards and Safety Authority (TSSA) is essential for safety and compliance. Failure to adhere to these codes can result in unsafe operation, posing risks to your property and loved ones. At Bremner Pools, we prioritize the strict adherence to TSSA regulations to guarantee the safety and efficiency of your pool heating system. Join us as we explore the critical TSSA codes governing the installation of natural gas and propane pool heaters, empowering you to make informed decisions for the well-being of your pool and household.

7.25.1
A pool heater shall be installed on a
(a) firm and level base; and
(b) non-combustible floor or support, except where the pool heater is
(i) certified for installation on a combustible floor;
(ii) installed using the pool heater manufacturer’s certified special base; or
(iii) installed as specified in Clause 4.13.3

7.25.2
Except where permitted by Clause 4.13.2, a pool heater shall be installed with the following
minimum clearances from combustible material:
(a) vertical – 18 in (450 mm);
(b) sides and rear – 18 in (450 mm)
(c) front – 48 in (1200 mm)

4.13.2
The clearances to combustible material specified in Clause 7 shall not be reduced unless
(a) such reduced clearance is certified as safe by a nationally recognized certification
organization acceptable to the authority having jurisdiction, and so marked on the appliance
nameplate; or
(b) protection is provided for the combustible material, and such reduced clearance are in
accordance with Table 4.1.

7.25.3
A pool heater installed outdoors shall be located a minimum of 18 in (450 mm) from any property line.

7.25.4
A wall-mounted pool heater shall be securely attached.

7.25.5
An outdoor pool shall not be installed beneath any structure, including a deck.

7.25.6
A pool heater of the finned-tube type shall be installed outdoors or in an enclosure that is not normally occupied and does not directly communicate with occupied areas. Direct-vent pool heaters of the finned-tube type are exempt from this requirement.

7.25.7
When a finned-tube indoor gas-fired pool heater that had prior approval for indoor installation that communicates with an occupied area, is being replaced with a new finned-tube-type heater, the heater shall be of the direct-vent type.

7.25.8
Where a heater is installed in accordance with clause 7.25.7, it shall be the responsibility of the owner of the heater to provide maintenance for the heater in accordance with the manufacturer’s instructions, but in no case less than once annually.

7.25.9
An outdoor pool heater shall be installed so that the flue discharge is in accordance with clause 8.14.10.

8.14.10
The flue gas discharge opening for an outdoor pool heater shall terminate not less than 10 ft (3m) from any building opening.

Adhering to TSSA codes is crucial for the safe and efficient installation of natural gas and propane pool heaters. At Bremner Pools, we prioritize compliance with these regulations to ensure the safety and satisfaction of our clients. Contact us today if you’re seeking professional pool heater installation services that prioritize safety and quality. Trust Bremner Pools to keep your pool heating system running smoothly and safely for years to come.